Anchor layout errors on core drilled walls are rarely caused by the drill. They come from the survey reference, the rig anchoring and the fact that a 100 mm core wanders more than a 25 mm hole. Fix the setup and the layout holds.
| Stage | Realistic tolerance |
|---|---|
| Survey set-out | +/-5 mm |
| Marking through to the wall | +/-3 mm over 3 m |
| Rig anchoring drift | +/-4 mm |
| Core wander (100 mm bit) | +/-3 mm at 200 mm depth |
| Anchor fixing position | +/-2 mm |
Stacked worst case is about 12 mm, which is why specifying +/-5 mm for a 100 mm core in a 150 mm wall is unrealistic. State a tolerance the chain can actually deliver, or add a slotted base plate.
For cores above 75 mm, drill a 12-16 mm pilot through first, then core. The pilot gives the core bit a fixed centre and removes the wander that dominates the tolerance budget. In reinforced walls, the pilot also finds the rebar before you commit a large diameter.
Anchor accuracy is the sum of small errors, not one big one. Writing the budget down before setting out turns a vague promise of "plus or minus a few millimetres" into something the crew can check at each step.
| Contributor | Typical allowance | How it goes wrong |
|---|---|---|
| Drawing and model transfer | 2-3 mm | Scaling from a PDF instead of setting out from coordinates |
| Set-out on the slab | 2-3 mm | Chalk line measured from an uneven wall instead of a reference datum |
| Rig placement and anchor | 2-5 mm | Vacuum base creeping on a dusty surface |
| Bit drift at entry | 2-4 mm | Starting without a pilot or a guide plate |
| Hole diameter vs anchor | As specified | Drilling at nominal bit size with a worn bit |
A 10 mm positional tolerance is realistic on a well-run site; 5 mm is achievable with a pilot and a fixed rig, and 3 mm needs a jig and a survey check. Promising 3 mm with a hand-held rig and chalk lines is how a first fix becomes a rework order.
On post-tensioned or heavily reinforced slabs, the layout check is not optional and the scan comes before the mark. Set-out accuracy is only worth anything if the hole is in a place where it is allowed to be.
The deliverable for an anchor layout job is not a finished wall, it is a record that lets the next trade trust the holes. Four items cover it, and any of them missing turns a clean job into a site argument.
Hand that over at the end of each pour or wall, not at the end of the project. Layout tolerances are argued about most often when the fixings are being installed months later, and by then nobody remembers which hole was moved or why.
If the structural engineer needs +/-3 mm, coring is the wrong process. Options: core oversize and grout the anchor in place, use a slotted base plate, or cast-in the anchors. Choosing coring and then arguing about tolerance on site costs more than either alternative.